Back to Menu

IGE

    
   THERMOMETER POCKET
    

Material : Impervious Graphite

Suitable for operating temperature up to 165°C depending upon the process fluid. Normal Test pressure 3 Kg/cm2 g. 

Nominal diameter

25

40

50

80

100

Lp : exposed length of pocket

Lp =

L – 35

L – 42

L – 42

L – 49

L – 64

 

A

ǿ62

ǿ82

ǿ102

ǿ132

ǿ160

 

B

25

30

30

35

50

 

C

20

20

20

25

25

 

D

ǿ108

ǿ127

ǿ152

ǿ190

ǿ229

 

E

PCD 79.5 4 holes ǿ 16

PCD 98.5 4holes ǿ 16

PCD 120.5 4 holes ǿ 19

PCD 152.5 8holes ǿ 19

PCD 190.5 8holes ǿ 19

    

TYPICAL ARRANGEMENT OF DILUTION-COOLING UNIT WITH INSTRUMENTATION

Click here for details

  

Login

Password

    New User > Click Here

About GI | Vision Statement | Strategic Business Unit | Management | Milestones & Success Stories | Green Company | Certification & Award | Consolidated Balance Sheet | Quarterly Results | Archives | News & Events | Product List A-Z  | GI Standards & Quality Statement | Product Ordering | Job Opportunities | GI Environment | Customer Login Area |  

    